Skip to content
Ahmad Ammar

D. Part IV: formulas, constants, symbols and corrections

D.1 Formulas

Quantity Formula Equation
Density \(\rho = m/V\) (32.1)
Ideal gas law \(p = \rho R_d T\), so \(\rho = p/(R_d T)\) (32.2)
Heat to change temperature \(Q = m c \Delta T\) (33.1)
Mixing two masses of water \(T_f = (m_hT_h + m_cT_c)/(m_h + m_c)\) (36.1)
Latent heat \(Q = mL\) (33.4)
Stefan–Boltzmann law \(E = \sigma T^4\) (33.2)
Wien’s law \(\lambda_{\max} = 2898\ \ensuremath{\mu\mathrm{m\,K}}/T\) (33.3)
Pressure \(p = F/A\) (34.1)
Hydrostatic pressure \(p = \rho g z\) (34.2)
Pressure with height \(p = p_0 e^{-z/H}\), \(H = R_dT/g\), halving height \(H\ln2\) (34.3)
Boyle’s law \(p_1V_1 = p_2V_2\) (34.4)
Adiabatic temperature change \(T_2/T_1 = (p_2/p_1)^{0.286}\) (34.5)
Buoyant force \(F_b = \rho_{\text{fluid}} V g\) (35.1)
Net force on a submerged object \(\Delta F = V g (\rho_{\text{object}} - \rho_{\text{fluid}})\) (35.3)
Parcel buoyancy \(a = g (T_p - T_e)/T_e\) (35.4)
Neutral ballast \(V_b = V - m/\rho\), \(\rho = m/(V - V_b)\) (37.1)

D.2 Constants used in this part

Constant Value Symbol
Gas constant for dry air 287 J kg\(^{-1}\) K\(^{-1}\) \(R_d\)
Specific heat of water / air (constant pressure) 4186 / 1006 J kg\(^{-1}\) K\(^{-1}\) \(c\), \(c_p\)
Latent heat of fusion / vaporisation of water 334 / 2260 J g\(^{-1}\) \(L_f\), \(L_v\)
Gravitational acceleration 9.81 m s\(^{-2}\) \(g\)
Standard sea-level pressure 101 325 Pa = 1 atm \(p_0\)
Stefan–Boltzmann constant \(5.67\times10^{-8}\) \(\mathrm{W\,m^{-2}}\) K\(^{-4}\) \(\sigma\)
Wien’s constant 2898 \(\mu\mathrm{m\,K}\) \(C\)
Kelvin offset 273.15

Precise values and sources for the shared constants are in Appendix E.

D.3 Corrections and clarifications to the handbook

The handbook (EGM305 module team n.d.) is sound; these points are worth knowing when you read it beside this part.

  1. Kelvin. It gives \(K = \ensuremath{^{\circ}\mathrm{C}}+ 273.16\) and calls 0\(^{\circ}\mathrm{C}\)the “freezing (or triple) point”. The conversion is \(+273.15\); 273.16 K (0.01\(^{\circ}\mathrm{C}\)) is water’s triple point. The 0.01 never matters at lab precision.

  2. Stefan–Boltzmann constant. It gives \(5.7\times10^{-8}\); the value is \(5.670\times10^{-8}\) \(\mathrm{W\,m^{-2}}\) K\(^{-4}\).

  3. “About 4000 times”. Per volume, water needs about 3400 times more heat than air to warm by 1\(^{\circ}\mathrm{C}\)(\(4.18\times10^6\) against \(1.23\times10^3\) J m\(^{-3}\) K\(^{-1}\), § 33.2); “thousands of times” is the safe statement.

  4. Latent heat of vaporisation. 2260 J g\(^{-1}\) is the value at 100\(^{\circ}\mathrm{C}\); at ocean-surface temperatures it is about 2450 J g\(^{-1}\), slightly larger.

  5. Pressure halving height. “About 5.6 km” corresponds to a scale height of about 8 km; with the real, colder upper air the halving height is 5 to 6 km (§ 34.2).

  6. Activity 1.1C materials: “Matched” should read “Matches”.

D.4 Symbols

Symbol Meaning Unit
\(\rho\) density kg m\(^{-3}\)
\(m\), \(V\) mass, volume kg, m\(^3\)
\(p\), \(F\), \(A\) pressure, force, area Pa, N, m\(^2\)
\(T\) temperature K (or \(^{\circ}\mathrm{C}\)where stated)
\(Q\), \(c\), \(L\) heat, specific heat capacity, latent heat J, J kg\(^{-1}\) K\(^{-1}\), J g\(^{-1}\)
\(E\), \(\lambda_{\max}\) emitted energy flux, peak wavelength \(\mathrm{W\,m^{-2}}\), \(\mu\mathrm{m}\)
\(z\), \(H\) height or depth, scale height m, km
\(g\) gravitational acceleration m s\(^{-2}\)
\(V_b\) ballast volume mL
\(a\) buoyant acceleration of a parcel m s\(^{-2}\)